Chemo-mechanical Hand Abrasion

Basic Functions

Damage to a surface by the human hand is one of the main reasons for the sustained disturbance of a product's valence. ABREX® tests the finished product or the lab sample regarding high-complex viscoelastic process of hand abrasion and its chemical environment.

Advantages:
  • Reproducible results due to standardised test procedure
  • Practice-oriented testing by chemo-mechanical abrasion
  • Universal use by flexible unit design

Soft chemo-mechanical hand-abrasion test acc. to:

  • DIN EN 60068-2-70 / IEC 68-2-70
  • BMW GS 97034 / GS 97045
  • Daimler DBL 7384
  • Ford WSS-M2P188-A1
  • EWIMA specification
  • Sony Ericsson 45/152 41- FEA 202 8139 Uen

as well as further company standards.

ABREX

Technical Data

Normal load: 1, 5, 10 N (6, 15, 20 N optional)
Rubbing path: 4 - 40 mm
Number of cycles: 1 - 10 million
Fluid feed: cyclic
Fabric feed: cyclic
Power supply: 230 V, 50 Hz; 110 V, 60 Hz
Compressed air: 4 bar, external, oil free, water free

Test samples:

New mobile phone key mobile phone key after the test New leather Leather after the test
Mobile phone keypad Leather

ABREX test construction

ABREX scheme

Options

industrial nail scratch test NailScratch 'Industrial':

Simulates the friction of a surface by human finger nail (e.g. printed, coated).


 

finger nail scratch test for automotive industries NailScratch 'Automotive':

Finger nail scratch test acc. to various test specifications for groove stability.


 

shoe sole test Shoe sole test:

Abrasion test acc. to various test specifications for testing the resistance against shoe soles.


 

Fingerprint test:

Affinity test of fingerprints and cleaning properties.

after approx. 10.000 cycles
measurement on mobile phone keyboard